INSULATED WIRE, INC.
203.791.1999
www.iw-microwave.com
sales@iw-microwave.com
Scan code to find
out how you can
get connected
We’re how the microwave industry gets connected!
INSULATED WIRE INC
TUF-FLEX offers an internal layer of silver plated copperweld
protection that is crush resistant & offers exceptional resistance to
kinking in lieu of external armor.
TUF-FLEX Cable Performance vs. Crush Force
Force
Max
Max Loss
(lbs)
VSWR
(dB)
0
1.20
1.3
45
1.20
1.3
90
1.20
1.3
160
1.20
1.3
200
1.22
1.3
225
1.28
1.3
Results of crush and bend tests on IW’s TUF-FLEX cable assemblies,
using 2 ft long samples of our 1803 cable. Results show max VSWR
and insertion loss over a frequency range of .04 to 18 GHz.
For crush force testing, the cable was placed between two 1 inch
diameter plates with force applied to the top plate. The same cable
was then tested using successively smaller bend radii to a minimum
bend radius of 1.5”.
Call us today with your project specs and we’ll show you the most
reliable way to get connected in the industry.
Tuf-Flex
Cables
When the going gets tough,
the tough
get connected!
A
Center Conductor
Silver plated OFHC
copper per ASTM
B-298
C
Shield
Silver plated
OFHC copper foil
E
Steel Serving
silver plated
copperweld per
ASTM B-501
B
Dielectric
Multi-ply PTFE
laminate per ASTM
D-1457
D
Braid
Silver plated
copper braid
F
Jacket
FEP per ASTM
D-2116
WWW.MPDIGEST.COM